In order to complement the performance of electronic ECT (eddy currenttest), the GMR(Giant Magneto Resistance) effect based crack ECT tech is studied.The working mechanism of the tech and the factors that influenced its performance are analyzed. The probe and signal processing circuit are designed, and then experiments to demarcate detect ability for crack is carried out.